  Datasheet File OCR Text:
  solid state relay g3na 1 new models with 75- a and 90-a output currents join the previous models with 5- to 50-a output currents. ? ac output relays with 75-a an d 90-a output currents have been added to the g3na series. ? all models feature a uniform mounting pitch. ? built-in varistor effectively absorbs external surges. ? operation indicator enables monitoring operation. ? protective cover for greater safety. ? standard models certified by ul and csa and -utu models by vde (tv). solid state relay g3na ordering information to order: select the part number and add the desired rated input voltage, (e.g., g3na-240b- 100 to 120 vac ) . isolation zero cross function indicator rated output load (applicable output load) rated input voltage model phototriac yes yes 5 a at 24 to 240 vac* (19 to 264 vac) 5 to 24 vdc g3na-205b photocoupler 100 to 120 vac 200 to 240 vac phototriac 10 a at 24 to 240 vac* (19 to 264 vac) 5 to 24 vdc g3na-210b photocoupler 100 to 120 vac 200 to 240 vac phototriac 20 a at 24 to 240 vac* (19 to 264 vac) 5 to 24 vdc g3na-220b photocoupler 100 to 120 vac 200 to 240 vac 25 a at 24 to 240 vac* (19 to 264 vac) 5 to 24 vdc g3na-225b 100 to 120 vac 200 to 240 vac 25 a at 200 to 480 vac* (180 to 528 vac) 5 to 24 vdc g3na-425b 100 to 240 vac (table continued on next page.)
2 solid state relay g3na *loss time increases under 75 vac. note: 1. when ordering a tv-approved model, add ?-ut u? to the model number as shown below: example: g3na-210b- utu. 2. g3na-4 are not ce marked. 3. g3na-2 with ?-utu? are ce marked. accessories heat sinks mounting track a nd accessories phototriac yes yes 40 a at 24 to 240 vac* (19 to 264 vac) 5 to 24 vdc g3na-240b photocoupler 100 to 120 vac 200 to 240 vac phototriac 75 a at 24 to 240 vac* (19 to 264 vac) 5 to 24 vdc g3na-275b-utu photocoupler 100 to 240 vac phototriac 90 a at 24 to 240 vac* (19 to 264 vac) 5 to 24 vdc g3na-290b-utu photocoupler 100 to 240 vac ? 10 a at 5 to 200 vdc* (4 to 220 vdc) 5 to 24 vdc g3na-d210b 100 to 240 vac yes 10 a at 200 to 480 vac* (180 to 528 vac) 5 to 24 vdc g3na-410b 100 to 240 vac 20 a at 200 to 480 vac* (180 to 528 vac) 5 to 24 vdc g3na-420b 100 to 240 vac 40 a at 200 to 480 vac* (180 to 528 vac) 5 to 24 vdc g3na-440b 100 to 240 vac 50 a at 200 to 480 vac (180 to 528 vac) 5 to 24 vdc g3na-450b 75 a at 200 to 480 vac (180 to 528 vac) 5 to 24 vdc g3na-475b-utu 100 to 240 vac 90 a at 200 to 480 vac (180 to 528 vac) 5 to 24 vdc g3na-490b-utu 100 to 240 vac isolation zero cross function indicator rated output load (applicable output load) rated input voltage model types applicable solid-state relays model standard mount g3na-205b, g3na-210b, g3na-d210b, g3na-220b, g3na-410b, g3na-420b y92b-a100 g3na-225b, g3na-240b, g3na-425b, g3na-440b y92b-a150n g3na-440b y92b-a250 track mount g3na-205b, g3na-210b, g3na-d210b, g3na-410b y92b-n50 g3na-220b, g3na-420b y92b-n100 g3na-225b, g3na-240b, g3na-425b, g3na-440b y92b-n150 g3na-450b y92b-p250 g3na-275b-utu, g3na-290b-utu, g3na-475b-utu, g3na-490b-utu y92b-p250nf description model mounting bracket for g3na-240b. changes pitch to 56 mm (2.21 in.) from 47.5 mm (1.73 in.), the same pitch as g3n-240b. r99-11 din rail track, 50 cm (1.64 feet) length; use with y92b-n ??? heat sinks pfp-50n din rail track, 1 m (3.28 feet) length; use with y92b-n ??? heat sinks pfp-100n spacer pfp-s end cap pfp-m one-touch mounting plate r99-12 for g3na
solid state relay g3na 3 specifications input ratings (ambient temperature: 25c [77f]) note: 1. the input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 1 20 vac, the input impedance is measured at 120 vac). 2. with constant current input circui t system, the impedance for the g3na-2 ?? b-utu is 15ma max. 3. refer to the ?characteristic data? for further details. output ratings *when the appropriate size omron heat sink is used. type rated voltage operating voltage range impedance (see note 1) voltage level must operate voltage must release voltage g3na-2 ?? b 5 to 24 vdc 4 to 32 vdc 7 ma max. (see note 2) 4 vdc max. 1 vdc min. 100 to 120 vac 75 to 132 vac 36 k 20% 75 vac max. (see note 3) 20 vac min. (see note 3) 200 to 240 vac 150 to 264 vac 72 k 20% 150 vac max. (see note 3) 40 vac min. (see note 3) g3na-4 ?? b 5 to 24 vdc 4 to 32 vdc 5 ma max. (see note 2) 4 vdc max. 1 vdc min. g3na-d210b 100 to 240 vac 75 to 264 vac 72 k 20% 75 vac max. 20 vac min. g3na-275b-utu g3na-290b-utu 5 to 24 vdc 4 to 32 vdc 15 ma max. (see note 2) 4 vdc max. 1 vdc min. g3na-475b-utu g3na-490b-utu 100 to 240 vac 75 to 264 vac 72 k 20% 75 vac max. 20 vac min. type applicable load rated load voltage load voltage range load current surge current with heat sink* without heat sink g3na-205b 24 to 240 vac 19 to 264 vac 0.1 to 5 a (at 40c) 0.1 to 3 a (at 40c) 60 a (60 hz, 1 cycle) g3na-210b 24 to 240 vac 19 to 264 vac 0.1 to 10 a (at 40c) 0.1 to 4 a (at 40c) 150 a (60 hz, 1 cycle) g3na-410b 200 to 480 vac 180 to 528 vac 0.2 to 10 a (at 40c) 0.2 to 4 a (at 40c) g3na-220b 24 to 240 vac 19 to 264 vac 0.1 to 20 a (at 40c) 0.1 to 4 a (at 40c) 220 a (60 hz, 1 cycle) g3na-420b 200 to 480 vac 180 to 528 vac 0.2 to 20 a (at 40c) 0.2 to 4 a (at 40c) g3na-240b 24 to 240 vac 19 to 264 vac 0.1 to 40 a (at 40c) 0.1 to 6 a (at 40c) 440 a (60 hz, 1 cycle) g3na-440b 200 to 480 vac 180 to 528 vac 0.2 to 40 a (at 40c) 0.2 to 6 a (at 40c) g3na-450b 200 to 480 vac 180 to 528 vac 0.2 to 50 a (at 40c) 0.2 to 6 a (at 40c) g3na-d210b 5 to 200 vdc 4 to 220 vdc 0.1 to 10 a (at 40c) 0.1 to 4 a (at 40c) 20 a (10 ms) g3na-275b-utu 24 to 240 vac 19 to 264 vac 1 to 75 a (at 40c) 1 to 7 a (at 40c) 800 a (60 hz, 1 cycle) g3na-475b-utu 200 to 480 vac 180 to 528 vac 1 to 75 a (at 40c) 1 to 7 a (at 40c) 800 a (60 hz, 1 cycle) g3na-290b-utu 24 to 240 vac 19 to 264 vac 1 to 90 a (at 40c) 1 to 7 a (at 40c) 1,000 a (60 hz, 1 cycle) g3na-490b-utu 200 to 480 vac 180 to 528 vac 1 to 90 a (at 40c) 1 to 7 a (at 40c) 1,000 a (60 hz, 1 cycle)
4 solid state relay g3na characteristics note: data shown are of initial value. type g3na-205b, -210b, -220b, -225b g3na-240b g3na-410b, -420b, -425b, -440b, -450b g3na- d210b g3na- 275b- utu g3na- 290b- utu g3na- 475b- utu g3na- 490b- utu operate time dc input 1/2 of load power source cycle + 1 ms ma x. 1 ms max. 1/2 of load power source cycle + 1 ms max. ac input 1 1/2 of load power source cycle + 1 ms max. 30 ms max. 3/2 of load power source cycle + 1 ms max. release time dc input 1/2 of load power source cycle + 1 ms max. 5 ms max. 1/2 of load power source cycle + 1 ms max. ac input 1 1/2 of load power source cycle + 1 ms max. 30 ms max. 3/2 of load power source cycle + 1 ms max. output on voltage drop 1.6 v (rms) max. 1.6 v (rms) max. 1.8 v (rms max.) 1.5 v max. 1.6 v (rms) max. 1.8 v (rms) max. leakage current 5 ma max. at 100 vac 10 ma max. at 200 vac 5 ma max. at 200 vdc 5 ma max. at 100 vac 10 ma max. at 200 vdc 10 ma max. at 200 vac 20 ma max. at 400 vac 10 ma max. at 200 vac 20 ma max. at 400 vac insulation resistance 100 m min at 500 vdc dielectric strength 2,500 vac, 50/60 hz for 1 minute 4,000 vac, 50/60 hz for 1 min. vibration malfunction 10 to 55 hz, 1.5 mm double amplitude shock malfunction 1,000 m/s 2 (approx. 100g) ambient temperature operating -30 to 80c (-22 to 176f) with no icing storage -30 to 100c (-22 to 212f) with no icing humidity 45% to 85% rh weight approx. 60 g (2.1 oz.) approx. 70 g (2.5 oz.) approx. 80 g (2.8 oz.) approx. 70 g (2.5 oz.) approx. 120 g (4.2 oz.)
solid state relay g3na 5 engineering data load current vs. ambient temperature note: the ambient operating temperature of the y92b-p250nf is ? 30 to 70 c. be sure the operating temperature is within this range. g3na-205b g3na-210b/410b g3na-220b/420b 20 16 10 8 6 5 4 2 0 ambient temperature ( c) ambient temperature ( c) ambient temperature ( c) load current (a) load current (a) load current (a) without heat sink without heat sink without heat sink with standard heat sink (y92b-a100 or y92b- n50) or aluminum plate measuring 75 mm x 75 mm x t3.2 mm (w x h x t) with standard heat sink (y92b-a100 or y92b- n50) or aluminum plate measuring 150 mm x 150 mm x t3.2 mm (w x h x t) with iron plate measuring 100 x 100 x t0.8 (w x h x t) with standard heat sink (y92b-a100 or y92b- n100) or aluminum plate measuring 200 mm x 200 mm x t3.2 mm (w x h x t) with iron plate measuring 100 x 100 x t0.8 (w x h x t) g3na-240b g3na-440b 50 45 40 30 20 12 10 6 4 2 g3na-450b load current (a) ambient temperature ( c) with standard heat sink (y92b-p250) without heat sink 50 45 40 30 20 12 10 6 4 2 ? 30 ? 20 0 20406080100 ? 30 ? 20 0 20406080100 ? 20 0 20406080100 0 0 60 50 40 30 20 10 6 0 ? 30 load current (a) ambient temperature ( c) load current (a) ambient temperature ( c) without heat sink without heat sink with standard heat sink (y92b-a150n or y92b-n150) with iron plate measuring 100 x 100 x t0.8 (w x h x t) with standard heat sink (y92b-a150n or y92b-n150) with iron plate measuring 100 x 100 x t0.8 (w x h x t) with y92b-a250 or heat sink with a radiation efficiency of 1 c/w. 70 60 50 40 35 30 20 12 7 100 80 90 0 100 80 60 70 40 20 0 ? 20 ? 30 2 4a g3na-275b-utu g3na-475b-utu g3na-290b-utu g3na-490b-utu 70 75 60 50 40 30 20 10 12 7 80 0 100 80 60 70 40 20 0 ? 20 ? 30 2 4a g3na-d210b 20 10 6 5 4 2 0 100 80 60 40 20 0 ? 20 ? 30 load current (a) ambient temperature ( c) load current (a) ambient temperature ( c) without heat sink without heat sink with iron plate measuring 100 x 100 x t0.8 (w x h x t) with iron plate measuring 100 x 100 x t0.8 (w x h x t) 0.6 c/w with heat sink using the y92b-p250nf 0.3 c/w with heat sink using the y92b-p250nf load current (a) ambient temperature ( c) without heat sink with standard heat sink (y92b-a100 or y92b-n50) or aluminum plate measuring 150 mm x 150 mm x t3.2 mm (w x h x t) with iron plate measuring 100 x 100 x t0.8 (w x h x t)
6 solid state relay g3na one cycle surge current the values shown by the solid line ar e for non-repetitive inrush currents. keep the inrush current below the values shown by the dotted line if it occurs repetitively. thermal resistance rth (back of junction ssr) (examples) thermal resistance rth of heat sinks (examples) note: when using a commercially avail able heat sink, use one with a thermal resistance equal to or less that the omron heat sink. 60 40 20 0 5,000 1,000 500 200 100 50 30 10 energized time (ms) inrush current (a peak) 150 100 50 0 5,000 1,000 500 200 100 50 30 10 energized time (ms) inrush current (a peak) 200 150 100 50 0 5,000 1,000 500 200 100 50 30 10 ener g ized time ( ms ) inrush current (a peak) 400 300 200 100 0 5,000 1,000 500 200 100 50 30 10 energized time (ms) inrush current (a peak) g3na-205b g3na-210b g3na-410b g3na-220b g3na-420b g3na-240b g3na-440b/-450b 28 30 26 24 22 20 18 16 14 12 10 8 6 4 2 0 2,000 1,000 500 200 300 100 50 70 30 20 10 ener g ized time ( ms ) inrush current (a peak) 900 800 700 600 500 400 300 200 100 0 1,000 100 50 300 30 10 ener g ized time ( ms ) inrush current (a peak) 1,200 800 1,000 600 400 200 0 1,000 100 50 300 30 10 ener g ized time ( ms ) inrush current (a peak) g3na-d210b g3na-275b-utu g3na-475b-utu g3na-290b-utu g3na-490b-utu 40 20 0 ? 20 ? 40 10 0 80 60 40 20 0 ? 20 ? 30 ambient temperature ( c) variation rate (%) 3,000 2,000 1,000 700 500 300 200 100 70 50 30 20 24 22 20 18 16 14 12 10 8 6 4 2 0 heat sink area (cm 2 ) load current ( a ) note: the heat sink area refers to the combined area of the sides of the heat sink that radiate heat. for example, when a current of 18 a is allowed to flow through the ssr at 40 c, the graph shows that the heat sink area is about 450 cm 2 . therefore, if the heat sink is square, one side of the heat sink must be 15 cm ( ) or longer. ambient temperature 80 c aluminum plate 3.2 mm thick ambient temperature 40 c 450 (cm 2 )/2 temperature characteristics (for must operate voltage and must release voltage) heat sink area vs. load current g3na-2 ?? b ac input g3na-220b model rth ( c/w) g3na-205b 3.22 g3na-210b 2.62 g3na-220b 1.99 g3na-240b 0.45 g3na-275b-utu g3na-475b-utu g3na-290b-utu g3na-490b-utu 0.45 g3na-d210b 2.62 model rth ( c/w) y92b-n50 2.8 y92b-n100 1.63 y92b-n150 1.38 y92b-a100 1.63 y92b-a150n 1.37 y92b-a250 1.00 y92b-p250nf 0.46
solid state relay g3na 7 dimensions relays note: all units are in millimeter s unless otherwise indicated. g3na-205b, g3na-210b, g3na-220b, g3na-410b, g3na-420b 13.8 12 3 4 ( ? ) (+) 4.5 25 47.5 44 47.6 0.2 25 max. 27 max. mounting holes output input load 4.5 dia. 43 max. 58 max. operating indicator four, m4 x 8 screws two, 4.3-dia. or m4 holes terminal arrangement/ internal connections (top view) load power supply 11.9 47.6 0.2 12 3 4 ( ? ) (+) g3na-240b, g3na-440b 13.8 47.5 44 4.5 25 11.9 mounting holes output input load 25 max. 27 max. 58 min. 4.5 dia. two, m5 x 12 screws 43 max. tw o, m 4 x 8 operating indicator two, 4.3-dia. or m4 holes load power supply terminal arrangement/ internal connections (top view) g3na-d210b 13.8 47.6 0.2 12 3 4 ( ? ) (+) ? + 4.5 25 47.5 44 note: the load can be connected to either the positive or negative side. 11.9 25 max. 27 max. mounting holes output input load 4.5 dia. 43 max. 58 max. four, m4 x 8 screws operating indicator two, 4.3-dia. or m4 holes terminal arrangement/ internal connections (top view) load power supply note: when connecting the load, either the positive or negative side of the load terminals can be connected. g3na-275b-utu, g3na-475b-utu, g3na-290b-utu, g3na-490b-utu 16.8 47.5 44 25 8.2 12 4.5 47.6 0.2 12 ( ? ) 4 (+) 3 mounting holes output input load 4.5 dia. two, m5 x 12 screws operating indicator two, 4.3-dia. or m4 holes terminal arrangement/ internal connections (top view) load power supply two, m4 x 8 screws 43 max. 58 max. 26 max. 28 max.
8 solid state relay g3na options (order separately) one-touch mounting plate the one-touch mounting plate is us ed to mount the gn3a to a din track. r99-12 for g3na (for the g3na and g3ne) ? when a relay is mounted to din trac k, use it within the rating for a relay without a heat sink. ? use the following din tracks: pfp-100n or pfp-100n2. mounting bracket heat sinks 30 44 two, m4 mounting holes for the g3ne two, m4 mounting holes for the g3na to mount the relay to din track, first mount it to the one-touch mounting plate and then attach it to the din track as shown in the diagram. to remove the relay from the din track, pull down on the tab with a screwdriver in the direction of the arrow. r99-11 (for the g3na-240b, g3na-440b) 4.6 5 6 21 12.5 16 8 4 5 use mounting bracket r99-11 so that the g3na-240b/-440b can be mounted with the same pitch as that of the g3n-240b. 5.6 47.6 90 0.3 35 30.5 0.3 30 5 4.5 6 35 0.2 90 0.4 mounting holes 4.6 dia. two, m3 holes two, m4 holes 77 max. 100 max. 44 max. 47 max. 51 max. weight: approx. 200 g two, 3.2-dia. holes two, 4.4-dia. or m4 holes the orientation indicated by the external dimensions is not the correct mounting orientation. when opening mounting holes, refe r to the mounting hole dimensions. for surface mounting, a 30% derating of the load current is required (from the load current vs. ambient temperature graphs). y92b-n50 heat sink (for the g3na-205b, g3na-210b, g3na-d210b, g3na-410b, g3ne-210t(l))
solid state relay g3na 9 y92b-n100 heat sink (for the g3na-220b, g3na-420b, g3ne-220t(l)) 35 30.5 0.3 47.6 90 0.3 5.6 5 4.5 28 13 35 0.2 30 the orientation indicated by the external dimensions is not the correct mounting orientation. when opening mounting holes, refe r to the mounting hole dimensions. for surface mounting, a 30% derating of the load current is required (from the load current vs. ambient temperature graphs). 90 0.4 4.6 dia. two, m3 holes 77 max. 100 max. 71 max. 100 max. 75 max. two, 3.2-dia. holes mounting holes weight: approx. 400 g two, m4 holes two, 4.4-dia. or m4 holes y92b-n150 heat sink (for the g3na-240b, g3na-440b) 35 47.6 5.6 5 4.5 30 90 0.3 56 0.3 13 28 the orientation indicated by the external dimensions is not the correct mounting orientation. when opening mounting holes, refe r to the mounting hole dimensions. for surface mounting, a 30% derating of the load current is required (from the load current vs. ambient temperature graphs). 4.6 dia. 77 max. 100 max. 100 max. 30 100 max. two, 3.2-dia. holes 104 max. mounting holes weight: approx. 560 g two, 4.4-dia. or m4 holes three, m4 holes 80 max. 47.6 m4 thermostat nc contact, 90c 64 120 105 120 max. 133.4 fan power supply, 200 vac 50/60 hz 160 max. 172 max. 110max. 64 0.3 130 0.3 y92b-p250nf heat sink (for the g3na-275b-utu, g3na-475b-utu, g3na-290b-utu, g3na-490b-utu) the orientation indicated by the external dimensions is not the correct mounting orientation. when opening mounting holes, refe r to the mounting hole dimensions. two, 4.6-dia. holes mounting holes weight: approx. 560 g two, 4.5-dia. or m4 holes two, m4 holes observe the precautions given in mounting method under precautions for correct use .
10 solid state relay g3na y92b-p250 70 max. four, m4 four, r2.5 130.5 max. 190.5 max. mounting holes four, 4.5 dia. or m4 y92b-a100 y92b-a150 y92b-a250 47.6 50 0.1 47.6 50 0.1 56 0.5 r2.2 r2.2 47.6 50 0.1 56 0.5 1.5 9.6 2 1.5 30 90 0.1 90 0.1 90 0.1 y92b-a100 heat sink (for the g3na-205b, g3na-210b, g3na- 220b, g3na-410b, g3na-420b, g3na- d210b) y92b-a150n heat sink (for the g3na-240b, g3na-440b) y92b-a250 heat sink (for the g3na-440b) the orientation indicated by the external dimensions is not the correct mounting orientation. when opening mounting holes, refe r to the mounting hole dimensions. for surface mounting, a 30% derating of the load current is required (from the load current vs. ambient temperature graphs). mounting holes two, m4 holes 100 max. three, m4 holes 150 max. three, m4 holes 250 max. 80.5 max. 45.5 max. four, 4.3-dia. or m4 holes 102 max. weight: approx. 210 g weight: approx. 310 g weight: approx. 510 g
solid state relay g3na 11 approvals ul (file no. e64562)/ csa (file no. lr35535) note: 1. when used with the proper omron he at sink part number or an appr opriately dimensioned equivalent. 2. the rated values approved by each of the safety standards (e.g., ul, csa, and tuv) may be different from the performance charac ter- istics individually def ined in this catalog. 3. in the interest of product improvemen t, specifications are subject to change. ssr type input voltage load type contact ratings without heat sink with heat sink (see note 1) g3na-205b 5 to 24 vdc 100 to 120 vac 200 to 240 vac general use/tungsten 3 a, 240 vac 5 a, 240 vac motor 2.5 fla, 15 lra, 240 vac 2.5 fla, 15 lra, 240 vac g3na-210b general use/tungsten 4 a, 240 vac 10 a, 240 vac motor 2.5 fla, 15 lra, 240 vac 5 fla, 30 lra, 240 vac g3na-220b general use/tungsten 4 a, 240 vac 20 a, 240 vac motor 2.5 fla, 15 lra, 240 vac 10 fla, 60 lra, 240 vac g3na-225b general use/tungsten 4 a, 240 vac 25 a, 240 vac motor 2.5 fla, 15 lra, 240 vac 12 fla, 72 lra, 240 vac g3na-240b general use/tungsten 6 a, 240 vac 40 a, 240 vac motor 5 fla, 30 lra, 240 vac 20 fla, 120 lra, 240 vac g3na-410b 5 to 24 vdc 100 to 240 vac general use/tungsten 4 a, 480 vac 10 a, 480 vac motor 2.5 fla, 15 lra, 480 vac 5 fla, 30 lra, 480 vac g3na-420b general use/tungsten 4 a, 480 vac 20 a, 480 vac motor 2.5 fla, 15 lra, 480 vac 10 fla, 60 lra, 480 vac g3na-425b general use/tungsten 4 a, 480 vac 25 a, 480 vac motor 2.5 fla, 15 lra, 480 vac 12 fla, 72 lra, 480 vac g3na-440b general use/tungsten 6 a, 480 vac 40 a, 480 vac motor 5 fla, 30 lra, 480 vac 20 fla, 120 lra, 480 vac g3na-450b general use/tungsten 6 a, 480 vac 50 a, 480 vac motor 5 fla, 30 lra, 480 vac 24 fla, 144 lra, 480 vac g3na-d210b general use 4 a, 200 vdc 10 a, 200 vdc
12 solid state relay g3na safety precautions precautions for safe use although omron continuously strive s to improve the quality and reliability of our relays, the g3na contains semiconductors, which are generally prone to occasi onal malfunction and failure. maintaining safety is particularly difficult if a relay is used outside of its ratings. always use the g3na wi thin the rated values. when using the g3na, always design the system to ensure safety and prevent human accidents, fires, and social damage even in the event of g3na failure, including system redundancy, measures to prevent fires from spreading, and desi gns to prevent malfunction. 1. g3na malfunction or fire damage may occasionally occur. do not apply excessive voltage or current to the g3na terminals. 2. heat dissipation ? do not obstruct the airflow to the g3na or heat sink. doing so may cause the output element to short, or cause fire damage. ? be sure to prevent the ambient temperature from rising due to the heat radiation of the g3na. if the g3na is mounted inside a panel, install a fan so that the inte rior of the panel is fully venti- lated. ? mount the g3na in the specified orientation. if the g3na is mounted in any other orientation, abnormal heat generation may cause output elements to short or may cause burning. ? do not use the g3na if the heat sink fins are bent, e.g., as the result of dropping the g3na. heat dissipation char acteristics will be reduced, possibly c ausing g3na failure. ? apply a thin layer of toshiba si licone?s yg6260 or sinetsu sili- cone?s g746, or a similar product to the heat sink before mount- ing. ? if a material with high thermal resistance, such as wood, is used, heat generated by the g3na may occasiona lly cause fire or burning. when installing the g3na directly into a control panel so that the panel can be used as a heat sink, use a panel material with low thermal resistance, such as aluminum or steel. ? use the specified heat sink or one with equivalent or better char- acteristics. 3. wire the g3na and tighten screws correctly, observing the follow- ing precautions heat generated by a terminal error may occasionally result in fire damage. do not operate if the screws on the output terminal are loose. ? abnormal heat generated by wires may occasionally result in fire damage. use wires suitable for the load current. ? abnormal heat generated by term inals may occasionally result in fire damage. do not operate if the screws on the output termi- nal are loose. tightening torque ? abnormal heat generated by term inals may occasionally result in fire damage. when tightening terminal screws, be sure that no non-conductive foreign ma tter is caught in screw. ? for gn3a relays of 40 a or higher, use crimp terminals of an appropriate size for the wire diameter for m5 terminals. ? do not use any wires with damaged sheaths. these may cause electric shock or leakage. ? do not place wiring in the same conduit or duct as high-voltage lines. induction may cause malfunction or damage. ? use wires of an appropriate length, otherwise malfunction and damage may result due to induction. ? mount the din track securely. otherwise, the din track may fall. ? be sure that the g3na clicks into place when mounting it to din track. the g3na may fall if it is not mounted correctly. ? do not mount the g3na when your hands are oily or dirty, e.g., with metal powder. these may cause g3na failure. ? tighten the g3na screws securely. tightening torque: 0.78 to 0.98 n ? m ? tighten the heat sink screws securely. tightening torque: 0.98 to 1.47 n ? m 4. preventing overheating when using the high-capacity h eat sink (y92b-p250nf), always use a thermostat or other method to protect from overheating in the event that the fan stops. 5. do not touch fan blades when the fan is operating, do not touch the fan blades with any part of your body or allow foreign matter to come into contact with the blades. always attach the enclosed finger guard when using the g3na. 6. operating conditions ? only use the g3na with loads that are within the rated values. using the g3na with loads outside the rated values may result in malfunction, damage, or burning. ? use a power supply within the rated frequency range. using a power supply outside the rated frequency range may result in malfunction, damage, or burning. 7. do not transport the g3na under the following conditions. failure or malfunction may occur. ? conditions under which the g3na will be exposed to water ? high temperatures or high humidity ? without proper packing touching the charged section may occasionally cause minor electric shock. do not touch the g3na terminal sec- tion (the charged section) when the power supply is on. be sure to attach the cover before use. the g3na and heat sink will be hot and may occasionally cause minor burns. do not touch the g3na or the heat sink either while the power supply is on, or immediately after the power is turned off. the internal snubber circuit is charged and may occasion- ally cause minor el ectric shock. do not touch the g3na?s main circuit terminals immediately after the power is turned off. be sure to conduct wiring with the power supply turned off, and always attach the terminal cover after complet- ing wiring. touching the terminals when they are charged may occasionally result in minor electric shock. do not apply a short-circuit to the load side of the g3na. the g3na may rupture. to protect against short-circuit accidents, install a protecti ve device, such as a quick- burning fuse, on the power supply line. ! caution ! caution ! caution ! caution ! caution screw size tightening torque m4 1.2 n ? m m5 2.0 n ? m
solid state relay g3na 13 operating and storage locations do not use or store the g3na in the following locations. doing so may result in damage, malfunction, or deterioration of performance characteristics. precautions for correct use please observe the following precaut ions to prevent failure to oper- ate, malfunction, or undesirabl e effect on product performance. before actual operation 1. the g3na in operation may cause an unexpected accident. therefore it is necessary to test the g3na under the variety of conditions that are possible. as for the characteristics of the g3na, it is necessary to consider differences in characteristics between individual ssrs. 2. unless otherwise specified, the ra tings in this catalog are tested values in a temperature range between 15c and 30c, a relative humidity range between 25% and 85%, and an atmospheric pres- sure range between 88 and 106 kpa (standard test conditions according to jis c5442). it will be necessary to provide the above conditions as well as the load cond itions if the user wants to con- firm the ratings of specific g3nas. mounting method ssr mounting pitch (panel mounting) relationship between ssrs and duct height ventilation outside the control panel if the air inlet or air outlet has a filter, clean the filter regularly to pre- vent it from clogging to ens ure an efficient flow of air. do not locate any objects around t he air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. a heat exchanger, if used, should be located in front of the ssrs to ensure the efficiency of the heat exchanger. ? please reduce the ambient temperature of ssrs. the rated load current of an ssr is measured at an ambient temperature of 40 c. ? an ssr uses a semiconductor in the output element. this causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. to restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the pa nel. this will reduce the ambient temperature of the ssrs and thus increase reliability. (generally, each 10 c reduction in temperature will double the expected life.) example: for 10 ssrs with load currents of 10 a, 0.16 x 10 = 1.6 thus, 2 fans would be required. size of fans: 92 mm 2 , air volume: 0.7 m 3 /min, ambient temperature of control panel: 30 c if there are other instruments that generate heat in the control panel other than ssrs, additional vent ilation will be required. ? do not use or store in locations subject to direct sunlight. ? do not use in locations subject to ambient temperatures outside the range ?20 to 60 c. ? do not use in locations subject to relative humidity outside the range 45% to 85% or locations subject to condensation as the result of severe changes in temperature. ? do not store in locations subject to ambient temperatures outside the range ?30 to 70 c. ? do not use or store in locations subject to corrosive or flammable gases. ? do not use or store in locations subject to dust (especially iron dust) or salts. ? do not use or store in locations subject to shock or vibration. ? do not use or store in locations subject to exposure to water, oil, or chemicals. ? do not use or store in locations subject to high temperatures or high humidity. ? do not use or store in locations subject to salt damage. ? do not use or store in locations subject to rain or water drops. 60 mm min. 80 mm min. 30 mm min. duct vertical direction load current (a) 5 a 10 a 20 a 40 a 75 a 90 a required number of fans per ssr 0.08 0.16 0.31 0.62 1.2 1.44 countermeasure 1 countermeasure 2 duct duct vertical direction do not surround the ssr with ducts, otherwise the heat radiation of the ssr will be adversel y affected. use short ducts. if the ducts cannot be shortened, place the ssr on a metal base so that it is not surrounded b y the ducts. 50 mm max. (a height of no more than half the ssr's height is recommended.) airflow mounting surface mounting surface mounting surface incorrect example duct duct duct base be aware of airflow air inlet ventilation outlet (axial fan) duct
14 solid state relay g3na high-capacity heat sink (y92b-p250nf) din-track mounting ? assembled din tracks are heavy. mount the din tracks securely. be sure that the heat sink is securely locked to the din track. ? attach end plates (pfp-m, order separately) to both ends of the units on the din track to hold them in place. ? to mount a heat sink to a din track, press down at the point indi- cated by arrow 1 in the diagram and then press in the heat sink at the point indicated by arrow 2. applicable din track mounting is possible on te35-15fe (iec 60715) din tracks. din tracks from the following manufacturers can be used. direct mounting ? prepare mounting holes as shown in the diagram. tightening torque: 0.98 to 1.47 n ? m ? when mounting a heat sink directly, first remove the fan unit, then mount the heat sink by itself before attaching the fan unit again. (remove the two screws show n in the following diagram.) ? first, temporarily mount the heat sink with the bottom two screws and then attach the top two screws with the mounting bracket sand- wiched between the heat sink and mounting surface. finally, tighten all four screws. ratings and char acteristics of high- capacity heat sink (y92b-p250nf) fan ratings note: average values. thermostat ratings fan/thermostat characteristics ? use a commercial power supply (50/60 hz) for the fan. ? be sure to turn off the power supply and wait for the blades to stop before inspecting the fan. ? high-precision ball bearings are used in the fan and these may be damaged if the fan is dropped or otherwise subjected to shock. the life and characteristics of t he fan will be reduced if the bear- ings are damaged. do not su bject the fan to shock. ? the life of the fan depends on the ambient temperature, as a guideline, the fan life is 40,000 hours for continuous usage at 40c. ? be sure there are no objects near the air vents that would restrict air flow and no loose objects, such as electrical lines. ? the tightening torque of the mounting screw when replacing the fan is 0.38 to 0.50 n?m. ? terminals equivalent to faston #110 are used for the fan power supply terminals. ? connect the ground screw hole on the fan to pe. manufacturer thickness: 1.5 mm thickness: 2.3 mm schneider am1-de2000 --- wago 210-114 or 210-197 210-118 phoenix n35/15 n35/15/15-2.3 vertical 64 130 0.3 remove screws fan unit heat sink rated voltage 200 v operating voltage 85% to 110% of rated voltage frequency 50/60 hz rated current (see note.) 0.085 a at 50 hz 0.072 a at 60 hz rated speed (see note.) 2,500 r/min at 50 hz 2,850 r/min at 60 hz operating temperature approx. 90 c contact ratings 3 a at 240 vac, resistive load 3 a at 24 vdc, resistive load insulation class (fan) vde: e (120 c) ul: a (105 c) csa: b (130 c) protection class 1 insulation resistance 100 m min. (at 500 vdc) between power supply connections and non-charged metal part dielectric strength fan: thermostat: 2,000 vac for 1 min 1,500 vac for 1 min between power supply connections and non- charged metal part ambient operating temperature ? 30 to 70 c (with no icing) storage temperature ? 40 to 85 c (with no icing) ambient operating humidity 25% to 85%
solid state relay g3na 15 preventing overheating with a high- capacity heat sink (y92b-p250nf) ? when the high-capacity heat sink is used, high-capacity switching at 75 a or 90 a requires forced cooling with a fan. connect the fan to a power supply according to its ratings specifications. ? if the fan stops due to a power supply error, due to foreign matter in the power supply connection, or due to aging, the heat sink will heat to high temperatures, possibl y resulting in failure of the ssr or adverse affects on other devices. implement an overheating pre- vention measure, such as turning off the load current, if the heat sink overheats. ? a thermostat is provided to detect overheating. the thermostat uses a nc contact, i.e., the circuit will be opened for overheating. this thermostat can be used to stop the operation of the ssr. implement an overheating preventi on measure by using this signal to output an alarm or perform another response applicable to the system. also, confirm that there is no problem with the overall sys- tem. ? do not connect the thermostat directly to the load power supply. connect it to a contactor or other shutoff device connected above the ssr. ? terminals equivalent to faston #187 are used for the thermostat terminals. ? do not place heat-dissipating silicon grease on the thermostat. ? do not solder the thermostat terminals. ? the following diagram shows a protective circuit example. ventilating a high-cap acity heat sink (y92b-p250nf) ? refer to ventilation outside the control panel . operating conditions ? do not apply currents exceeding the rated current otherwise, the temperature of the g3na may rise excessively. ? as protection against accidents due to short-circuiting, be sure to install protective devices, such as fuses and no-fuse breakers, on the power supply side. ? do not apply overvoltages to the i nput circuit or output circuit. fail- ure or burning may result. ? do not drop the g3na or otherwise subject it to abnormal shock. malfunction or failure may result. ? keep the cooling system runni ng continuously during the on/off operation of the ssr. this is to allow residual heat to dissipate while the ssr is off. noise terminal voltage according to en55011 the g3na-utu complies with en55011 standards when a capacitor is connected to the load power suppl y as shown in the following cir- cuit diagram. ? connect capacitor c1 to both sides of the input terminals for a g3na with a dc input. ? connect capacitor c2 to both sides of the load power supply out- put. ? connect the varistor to both sides of the g3na output terminals. ? do not use an input line that is longer than 3 m. loss time the loss time will increase when the g3na is used at a low applied voltage or current. be sure that this does not cause any problems. using dc loads for a dc or l load, a diode should be connected in parallel the load to absorb the counter electromotive force of the load. fuses connect a quick-break fuse in series with the load as a short-circuit protection measure. use one of the fuses in the following table or one with equivalent or better characteristics. recommended fuses reverse connection the output terminal side of the g3na-d210b is connected to a built- in diode to protect the ssr from damage that may result from reverse connection. the ssr, however, cannot withstand one minute or more if the wires are connected in reverse. therefore, pay the utmost attention not to make polarity mistakes on the load side. load g3na load side input side y92b-p250nf thermostat (nc contact) circuit breaker (contact side) coil power supply circuit breaker circuit breaker (coil side) output input c1 c2 g3na-utu type load capacitor c1 0.1 f 3 m max. varistor ? g3na-2 @@ : 470 v, 0.6 w ? g3na-4 @@ : 910 v, 0.8 w capacitor c2 ? g3na-2 @@ : 1 f, 250 vac ? g3na-4 @@ : 0.5 f, 500 vac g3na rated load current fuse model manufacturer applicable ssr 5 a 60lff5 kyosan electric manufacturing company g3na-205b 8 a 60lff8 g3na-210b 10 a 60lff10 15 a 60lff15 g3na-220b 20 a 60lff20 50sha20 25 a 60pff25 50sha25 g3na-240b 30 a 60pff30 50sha30 40 a 50sha40 45 a 50sha45 50 a 50sha50 g3na-275b-utu 75 a 50sha75 80 a 50sha80 g3na-290b-utu 100 a 50shb100 loss time ssr input load load power supply
16 solid state relay g3na precautions on operating and storage environments 1. operating ambient temperature the rated value for the ambient operating temperature of the g3na is for when there is no heat build- up. for this reason, under condi- tions where heat dissipation is not good due to poor ventilation, and where heat may build up easily, the actual temperature of the g3na may exceed the rated value result ing in malfunction or burning. when using the g3na, design the s ystem to allow heat dissipation sufficient to stay below the load current vs. ambient temperature characteristic curve. note also t hat the ambient temperature of the g3na may increase as a result of environmental condi tions (e.g., cli- mate or air-conditioning) and operating conditions (e.g., mounting in an airtight panel). 2. transportation when transporting the g3na, observe the following points. not doing so may result in damage, malfunction, or deterioration of perfor- mance characteristics. ? do not drop the g3na or subject it to severe vibration or shock. ? do not transport the g3na if it is wet. ? do not transport the g3na under high temperatures or humidity. ? do not transport the g3na without packing it properly. 3. vibration and shock do not subject the g3na to excessi ve vibration or shock. otherwise the g3na may malfunction and internal components may be deformed or damaged, resulting in failure of the g3na to operate. to prevent the g3na from abnormal vibration, do not install the g3na in locations or by means that will subject it to vibration from other devices, such as motors. 4. solvents do not allow the g3na or the resin portion of the fan?s thermostat to come in contact with solvents, such as thinners or gasoline. doing so will dissolve the ma rkings on the g3na. 5. oil do not allow the g3na terminal cover to come in contact with oil. doing so will cause the cove r to crack and become cloudy. 1. leakage current a leakage current flows through a s nubber circuit in the g3na even when there is no power input. therefore, always turn off the power to the input or load and check that it is safe before replacing or wiring the g3na. 2. screw tightening torque tighten the g3na terminal screws properly. if the screws are not tight, the g3na will be damaged by heat generated when the power is on. perform wiring using t he specified tightening torque. 3. handling relays do not mount the g3na when your hands are oily or dirty, e.g., with metal powder. these may cause g3na failure. 4. do not drop be careful not to drop a relay or heat sink onto any part of your body while working. injury may result. this is particularly true for the high-capacity heat sink (y92b- p250nf), which weighs 2.5 kg. operation input circuit trigger circuit switch element snubber circuit varistor leakage current
solid state relay g3na 17 omron electronic components, llc terms and conditions of sales 1. definitions : the words used herein ar e defined as follows. (a) terms: these terms and conditions (b) seller: omron electronic com ponents llc and its subsidiaries (c) buyer: the buyer of products, including any end user in section iii through vi (d) products: products and/or services of seller (e) including: including without limitation 2. offer; acceptance: these terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of products by seller. seller hereby objects to any terms proposed in buyer's purchase order or other documents which are inco nsistent with, or in addition to, these ter ms. 3. distributor : any distributor shall inform its custom er of the contents after and including section iii of these terms. 1. prices; payment : all prices stated are current, subject to change without notice by seller. buyer agrees to pay the price in effect at time of shipment. payments for products received are due net 30 days unless otherwise stated in the invoice. buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. discounts : cash discounts, if any, will apply only on the net amount of invoices sent to buyer after deducting transportation charges , taxes and duties, and will be allowed only if (a) the invoice is paid according to seller's payment terms and (b) buyer has no past due amounts owing to seller. 3. interest : seller, at its option, may charge buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. orders : seller will accept no order less than 200 u.s. dollars net billing. 5. currencies : if the prices quoted herein are in a currency other than u.s. dollars, buyer shall make remittance to seller at the then current exchange rate most favorable to seller; provided that if remittance is not made when due, buyer will convert the amount to u.s. dollars at the then current exchange rate most favorable to seller available during the period between the due date an d the date remittance is actually made. 6. governmental approvals : buyer shall be responsible for all costs involved in obtaining any government approvals regarding the im portation or sale of the products. 7. taxes : all taxes, duties and other governmental charges (other than general real property and income taxes) , including any interest or penalti es thereon, imposed directly or indirectly on seller or required to be collected directly or indirectly by seller for the manufacture, production, sale, delivery, importation, consumption or use of the products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by buyer to seller. 8. financial : if the financial position of buyer at any time becomes unsatisfactory to seller, seller reserves the right to stop shipments or require satisfactory security or payment in advance. if buyer fails to make payment or otherwise comply with these terms or any related agreement, seller may (without liability and in addition to other remedies) cancel any unshipped portion of products sold hereu nder and stop any products in transit until buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by buyer. buyer shall in any event remain liable for all unpaid accounts. 9. cancellation; etc: orders are not subject to rescheduling or cancellation unless buyer indemnifies seller fully against all costs or expenses arising in connection therewith. 10. force majeure : seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquak es, fires, floods, strikes or other labor disputes, shortage of labor or ma terials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or t he requirements of any government authority. 11. shipping; delivery: unless otherwise expressly agreed in writing by seller: (a) all sales and shipments of products shall be fob shipping point (unless otherwise stated in writing by seller) , at which point title to and all risk of loss of the products shall pass from seller to buyer, provided that seller shall retain a security interest in the products until the full purchase price is paid by buyer; (b) delivery and shipping dates are estimates only; and (c) seller will package products as it deems proper for protection against normal handling and extra charges appl y to special conditions. 12. claims: any claim by buyer against seller for shortage or damage to the products occurring before delivery to the carrier must be presented in detail in writing to seller within 30 days of receipt of shipment. 1. suitability: it is the buyer?s sole respoinsibility to ensure that any omron product is fit and sufficient for use in a motorized vehicle application. buyer shall be solely responsible for determining appropriateness of the particular product with respect to the buyer?s application including (a) electrical or electronic components, (b) circuits, (c) system assemblies, (d) end product, (e) system, (f) materials or substances or (g) operating environment. buyer acknowledges that it alone has determined that the products will meet their requirements of the intended use in all cases. buyer must know and observe all prohibitions of use appli cable to the product/s. 2. use with attention: the followings are some examples of applications for which particular attention must be given. this is not intended to be an exhaustive list of all possible use of any product, nor to imply that any use listed may be suitable for any product: (a) outdoor use, use involving potential chemical contamination or electrical interference. (b) use in consumer products or any use in significant quantities. (c) energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machi nes, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) systems, machines, and equipment that c ould present a risk to life or property. 3. prohibited use: never use the product for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the product is properly rated and installed for the intended use within the overall equipment or system. 4. motorized vehicle application: use of any product/s for a motorized vehicle application must be expressly stated in the specification by seller. 5. programmable products: seller shall not be responsible for the buyer's programming of a programmable product. 1. warranty : seller's exclusive warranty is that the products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by seller (or such other period expressed in writing by seller). seller makes no warranty or representation, express or implied, about all other warranties, non-infringement, merchantability or fitness for a particular purpose of the products. 2. buyer remedy : seller's sole obligation hereunder shall be to replace (in the form originally shipped with buyer responsible for labor charges for removal or replacement thereof) the non-complying product or, at se ller's election, to repay or credit buyer an amount equal to the purchase price of the pr oduct; provided that there shall be no liability for seller or its affiliates unless se ller's analysis c onfirms that th e products were handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modi fication. return of any products by buyer must be approved in writing by seller before shipment. 3. limitation on liability : seller and its affiliates shall not be liable for special, indirect, incidental or consequential damages, loss of profits or production or commercial loss in any way connected with the products, whether such claim is based in contract, warranty, negligence or strict liability. further, in no event shall liability of seller or its affilitates exceed the individual price of the product on which liability is asserted. 4. indemnities : buyer shall indemnify and hold harmless seller, its affiliates and its employees from and against all liabilitie s, losses, claims, costs and expenses ( including attorney's fees and expenses ) related to any claim, investig ation, litigation or proceeding ( whether or not seller is a party ) which arises or is alleged to arise from buyer's acts or omissions under these terms or in any way with respect to the products. 1. intellectual property : the intellectual property embodied in the products is the exclusive property of seller and its affiliates and buyer shall not attempt to duplicate it in any way without the written permission of seller. buyer (at its own expense) shall indemnify and hold harmless seller and defend or settle any action brought against seller to the extent that it is based on a claim that any product made to buyer specifications infringed intellectual property ri ghts of another party. 2. property; confidentiality : notwithstanding any charges to buyer for engineering or tooling, all engineering and tooling shall rema in the exclusive property of seller. all information and materials supplied by seller to buyer relating to the products are confidential and proprietary, and buyer shall limit distribution thereof to its trusted employees and strictly prevent di sclosure to any third party. 3. performance data : performance data is provided as a guide in determining suitability and does not constitute a warranty. it may represent the result of seller's test conditions, and the users must correlate it to actual application requirements. 4. change in specifications : product specifications and description may be changed at any time based on improvements or other reasons. it is seller?s practice to change part numbers when published ratings or feat ures are changed, or when significant engineering changes are made. however, some specifications of the product may be changed without any notice. 5. errors and omissions : the information on seller?s website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. export controls : buyer shall comply with all app licable laws, regulations and licenses regarding (a) export of the products or information provided by seller; (b) sale of products to forbidden or other proscribed persons or organizations; (c)disclosure to non-citizens of regulated technology or information. 1. waiver : no failure or delay by seller in exer cising any right and no course of dealing between buyer and seller shall operate as a waiver of rights by seller. 2. assignment : buyer may not assign its rights hereunder without seller's written consent. 3. law : these terms are governed by illinois law (without regard to conflict of laws) . federal and state courts in illinois have exclusive jurisdiction for any dispute hereunder. 4. amendment : these terms constitute the entire agreement between buyer and seller relating to the products, and no provision may be changed or waived unless in writing signed by the parties. 5. severability : if any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. i. general ii. sales iii. precautions iv. warranty and limitation v. information; etc. vi. miscellaneous
18 solid state relay g3na certain precautions on specifications and use 1. suitability for use . seller shall not be responsible for conformity with any stan- dards, codes or regulations which apply to the combination of the product in buyer's application or use of the product. at buyer's request, seller will pro- vide applicable third party certificat ion documents identifying ratings and limi- tations of use which apply to the product. this information by itself is not sufficient for a complete determination of the suitability of the product in com- bination with the end product, machine, system, or other application or use. buyer shall be solely responsible for determining appropriateness of the par- ticular product with respect to buyer's application, product or system. buyer shall take application responsibility in all cases but the following is a non- exhaustive list of applications for wh ich particular attention must be given: (i) outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or us es not described in this document. (ii) energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusem ent machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) use in consumer products or any use in significant quantities. (iv) systems, machines and equipment that could present a risk to life or property. please know and observe al l prohibitions of use applicable to this product. never use the product for an application involving serious risk to life or property with out ensuring that the system as a whole has been designed to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or sys- tem. 2. programmable products . seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. performance data . performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a war- ranty. it may represent the result of seller 's test conditions, and the users must correlate it to actual application requirem ents. actual performance is subject to seller's warranty and limitations of liability. 4. change in specifications . product specifications and accessories may be changed at any time based on improvement s and other reasons. it is our prac- tice to change part numbers when publ ished ratings or features are changed, or when significant constr uction changes are made. however, some specifica- tions of the product may be changed without any notice. when in doubt, spe- cial part numbers may be assigned to fi x or establish key specifications for your application. please cons ult with your seller representative at any time to confirm actual specificat ions of purchased product. 5. errors and omissions . the information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or pr oofreading errors, or omissions. 6. rohs compliance . where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the european union's directive on the restriction of certain hazardous substances ("rohs"), although the requirements of rohs do not take effect until july 2006. these requirements may be subject to change. please con- sult our website for current information. omron on-line global - http://www.omron.com usa - http://www.components.omron.com cat. no. j01c-e-01a printed in usa omron electronic components llc 55 e. commerce drive, suite b schaumburg, il 60173 847-882-2288 06/08 specifications subject to change without notice complete ?terms and conditions of sale? for product purchase and use are on omron?s website at http://www.components.omron.com ? under the ?about us? tab, in the legal matters section. all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.039 37. to convert grams into ounces, multiply by 0.03527.


▲Up To Search▲   

 
Price & Availability of G3NA-220B-AC100-120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X